When demulsifier solves one problem and cooks your exchanger

In our condensate stabilizer train, every time ops bumped the demulsifier, our E-205 shell-and-tube went from clean to molasses in a week. We chased velocity, baffle leakage, metallurgy, even blamed crude blend. Turned out the fix was polymerizing in hot zones and plating the tubes.
We rigged a cheap side-stream with a 40 µm strainer and a beaker-on-a-hot-plate test at process film temps to see if the dose browned. Moved the injection lance downstream of the hot bundle, cut rate 30%, and used DP across the coalescer as the feedback, not just water cut. Fouling interval went from 7 days to 9 months.
I can tweak turbulence and tube counts all day, but I need a fast way to flag a sticky chemical before it cooks on steel. What quick field screens do you trust? Hot-wall coupons, quartz crystal microbalance, stirred bomb, something I can run on site? I’m not wiring a cloud skid or waiting six weeks on a lab. What’s your go-to, field-grade and repeatable?

Login to comment

Login
Discussion

1 comment

Collapse this comment
chriskelvin 1 week ago
Two things that usually make a hotplate screen under-predict this kind of fouling:

1. Test at tube-wall temperature, not film temperature. On the hot-side surface the wall runs hotter than the bulk by roughly q/h, so a dose that stays clear at bulk or film temperature can still brown at the wall. Estimate the wall temperature from your exchanger duty and film coefficient and run the coupon there, plus a margin.

2. Test the concentration at the quill tip, not the diluted ppm. Near the injection point the chemical is close to neat, and that local overdose on hot steel is often where the polymer starts. Run a dose ladder: target ppm, 10x, and neat on a hot coupon.

For a repeatable field screen, a heated-tube test in the spirit of ASTM D3241 (the jet fuel thermal oxidation test, a heated tube with a tube-deposit rating) can be copied with a cartridge-heated carbon steel rod, a small pump, and a before/after weight or visual rating. It is not a standard method for your service, but it ranks candidates consistently.

Also trend fouling resistance from DCS data you already have: Rf = 1/U_dirty - 1/U_clean, with U from duty, area and LMTD. That flags a chemical change within days instead of waiting for DP or a bundle pull.