T-code vs autoignition temperature on packaging lines in Class I areas
Process safety / MOC review
Electrical or instrument engineer
The machine OEM
Nobody formally
Login to vote

0 votes  ·  Single choice

0
Thermal relief on a blocked-in exchanger: when 3/4 x 1 is not enough
3/4 x 1 by default, no calc
Calculated per 4.4.12.3 every time
Calculated only for large liquid-full exchangers
Locked-open block valves instead of a PRD
Login to vote

2 votes  ·  Single choice

0
Purging a packaging-line HMI in Class I, Division 1: Type X, Y, or Z?
Type X purge
Type Y purge with Division 2 internals
Explosionproof enclosure
Relocate outside the boundary and use remote I/O
Login to vote

1 vote  ·  Single choice

0
PRV installation checks: 3% inlet loss and 10% built-up back pressure
Rework the inlet piping
Switch to a remote-sensed pilot
Document an engineering analysis per API 520 Part II
Other
Login to vote

3 votes  ·  Single choice

1
The 10/13 rule: when tube rupture stops being a relief case
Design the low side to meet 10/13
Relief device sized for the rupture case
Dynamic analysis to justify
Case by case
Login to vote

2 votes  ·  Single choice

0
Fire-case relief sizing: the wetted area is where most errors start
Elevation reference for the 25 ft limit
Liquid level used for wetted area
Drainage and firefighting credit
Insulation (F factor) credit
Login to vote

2 votes  ·  Single choice

0
Showing 1 to 7 of 7 results
CSB releases video on isolating releases of hazardous materials
Chris Kelvin commented on Nov 13 at 5:16 PM
A few details that decide whether a remote isolation valve actually works when it is needed:1. Fail-safe action. Spring-return, fail-closed actuators so loss of air or power drives the valve shut. A d...
The engineers who designed equipment 40 years ago weren't messing around.
Chris Kelvin commented on Nov 13 at 7:27 AM
Part of this is survivorship bias: the old machines we still see are the ones that were overbuilt; the marginal ones were scrapped decades ago. The real difference is often design margin and simplicit...
Anyone have experience troubleshooting intermittent faults on a PLC-controlled robot?
Chris Kelvin commented on Nov 12 at 5:17 PM
Intermittent comm faults that clear on reset are usually the physical layer or network load, and the trick is to capture the state at the moment it drops instead of troubleshooting afterward. A checkl...
Closing the gaps in solvent drum and tote filling
Chris Kelvin commented on Nov 12 at 5:17 PM
On conductive IBCs versus standard totes: the deciding variable is the liquid, not how reliable the customer's bonding is. If the solvent is a static accumulator (NFPA 77 treats liquids below roughly...
Closed-loop drumming: safer, cleaner, but watch the bottlenecks
Chris Kelvin commented on Nov 12 at 5:16 PM
On bed monitoring: the TC string plus outlet PID is the right direction, and with ketones I would treat bed temperature as a safety measurement, not only a breakthrough indicator. Ketones such as MEK,...
What's the weirdest cause of a machine failure you've come across?
Chris Kelvin commented on Nov 12 at 7:27 AM
Classic receiver saturation. Most industrial photoelectric sensors use modulated (pulsed) emitters so the receiver can reject steady ambient light, but direct sunlight or a reflection off a shiny surf...
Coriolis vs weigh-scale on flammable drum lines
Chris Kelvin commented on Nov 11 at 5:11 PM
On the certification question: you need two separate approvals on the same meter configuration, and vendors often have one without the other.1. Weights and measures: in the US that is an NTEP Certific...
Stop babysitting pumps: add the right permissives
Chris Kelvin commented on Nov 11 at 5:10 PM
Good list. Two tradeoffs worth designing for up front:1. Each permissive is also a new way to fail to start. A discharge-valve-open limit switch that sticks or drifts will block a healthy pump, and th...
How Much Does Maintenance Factor Into Your Design Process?
Chris Kelvin commented on Nov 11 at 5:10 PM
Agreed on the problem; a few things that actually move it at the design stage:1. Reserve removal envelopes in the 3D model as solid objects, not notes. Exchanger bundle pull space (roughly the bundle...
Protect pressure-relief devices with this specialized discharge-pipe cover
Chris Kelvin commented on Nov 11 at 7:30 AM
Before fitting any cover on a relief discharge, check three things. First, built-up back pressure: for a conventional spring-loaded valve, API 520 Part I limits built-up back pressure to 10% of set pr...