Two numbers decide whether a correctly sized relief valve actually works once it's installed. On the inlet side, API 520 Part II limits the non-recoverable pressure loss from the protected equipment to the valve inlet to 3% of set pressure at rated flow. Above that, the valve can chatter, and the seat and guide damage that follows can keep it from reseating. On the outlet side, API 520 Part I limits built-up back pressure on a conventional spring-loaded valve to 10% of set pressure at 10% overpressure. Balanced-bellows and pilot-operated valves tolerate more, per the manufacturer's capacity curves.
Common causes of failing the inlet check are long or reduced inlet lines, isolation valves smaller than the valve inlet, and adding capacity to an existing header. Since the 2015 edition, API 520 Part II allows a documented engineering analysis as an alternative when 3% can't be met, but the analysis has to show stable operation, not just claim it. Fixes, roughly from best to worst: shorten or upsize the inlet, switch to a remote-sensed pilot valve, or do the engineering analysis and record it in the relief system design basis.
Poll: When an existing PRV fails the 3% inlet check, what do you usually do?